Watch list

 
Positioning system

PSS 30_/32_-14

 
 
 
 

Positioning system with protection class IP 65



 

Positioning system with protection class IP 65 for damp area applications

  • Positioning system with absolute measuring system, without battery
  • Hygienic design
  • Galvanic separation of motor and control unit prevents the control unit from being affected by any EM interference in the motor 
  • Easy mounting with hollow shaft possible (also available with solid circular shaft)
  • Absolute encoder eliminates the need for reference runs during system setup and installation of replacements
  • Easy address assignment directly on the device using integrated address switches (not for IO-Link)
  • Manual disconnecting lever permits manual disconnection of the gearbox
  • Regulation of the current torque prevents overloading and unnecessary run aborts
  • Strong breakaway torque enables safe start-up even after an extended standstill
  • Intelligent running behaviour. Recognises the difference between obstacles and dirt
  • Spindle offset run: Excludes inconsistencies due to lash in the spindle
  • Condition monitoring of supply voltage, drag error (permits optimum adjustment of current position), power consumption and torque

Design
Horizontal construction

Nominal torque / nominal rated speed

PSS 301-14: 1 Nm / 210 rpm
PSS 302-14: 2 Nm / 100 rpm
PSS 305-14: 5 Nm / 40 rpm
PSS 322-14: 2 Nm / 150 rpm
PSS 325-14: 5 Nm / 68 rpm

Bus communication
CANopen, PROFIBUS DP, DeviceNet, Modbus RTU, Sercos, EtherCAT, PROFINET, EtherNet/IP, POWERLINK, IO-Link

Positioning accuracy
0.9°

Output shaft
14 mm solid shaft (PSS 30_/32_-14-V) or
14 mm hollow shaft with adjustable collar

Positioning range
250 rotations, not subject to mechanical limits

Supply voltage
24 VDC

Protection class
IP 65 under installed and wired conditions

Supplied with 2nd data bus connection and address switches as standard (not for IO-Link).

Brake (optional), Solid Shaft (optional)

Set-up mode or manual positioning permits the connection of jog keys (optional, not for IO-Link).

NRTL certification in accordance with UL, CSA, ANSI and CE optional (standard CE)